IntraOs 70

Intraoral X-ray equipment for traditional and digital imaging.

IntraOs 70 is a traditional Intraoral x-ray machine designed to face the most demanding needs of the dental profession when using both traditional films and digital imaging receptors.

The main feature is the combination of 70KVp voltage potential with 7mA current and a wide range of exposure times from 60ms to 3.2 seconds.

  • Wall mounted or mobile
  • Sharp images with good radiographic contrast
  • Simple and affordable
  • Low dose setting for Digital receptors
  • Automatic compensation of mains fluctuations
  • Wide range of exposure times from 60ms to 3.2seconds
  • Auto set timer*
  • Each timer and each handset can be remotely mounted
  • Digital display of selected values
  • Pre setting for film sensitivity
  • Back up timer
  • Dead-man function for added safety
  • Selective alarm messages for extra safety
  • Round beam limiting device (20cm) focus to film distance 6cm output field diameter

Auto set is a digital timer with automatic exposure settings. Once the tooth type and the patient size have been selected the time values appear on the digital display. It also controls dose reduction when using digital receptors.

Technical Data:

TUBE HEAD

Type

Line voltage

Line current

High voltage potential

Anodic current

Focal spot

Duty cycle

Skin distance

Circular radiation field

Coaxial connection

Weight



Grid-control action

120VAC 50/60 Hz

6 A

70 kVp

7 mA

0.8 IEC 336/1982

1/30

20 cm

Diameter 6 cm

Free rotation in horizontal plane

14 lb (6.350 kg)

Mechanical system

The wall mounted suspension system includes:

  • Wall support
  • Short, medium and long extension arms, 17 ¾ inches (45.08 cm), 27 ½ inches (69.85 cm), and 35 ½ inches (90.15 cm) long.
  • Folding arm, useful reach of 55 inches (139.70 cm), 65 inches (165.10 cm), or 72 inches (182.88 cm) with short, medium or long extension arm respectively.

The mobile version is composed of:

  • Mobile base, 29 inches (73.66 cm) width, 42 inches (106.68 cm) height, 24 ½ inches (62.23 cm) depth.
  • Folding arm

Autoset Timer

Line voltage: 115VAC, 50/60 Hz

Microprocessor controlled functions

Zero-crossing power switching

Automatic setting of exposure time by object selection

Manual setting of exposure time from 60ms to 3.2 seconds (plus or minus 18 steps)

Child or Adult patient selection

‘Low dose’ setting for digital receptors

Hand-switch provided with 10 inch coiled cord

Automatic compensation of mains fluctuations selectable on request

Back-up timer

Timer and hand-switch can be remotely mounted


 
 
 