DRC

Sigma Bio-Ray SDX

True plug and play system, FDA approved. High resolution.
EXPERIENCE THE DIFFERENCE. Small pixel size, fiber-optic plate, and needle structure scintillator makes the Bio-Ray SDX superior in resolution and image quality. From direct digital panoramic to phosphor plate systems, Sigma Digital X-Ray offers a turnkey solution for all your digital imaging needs. And Bio-Ray SDX will give you the best technology available for a reasonable price. Call us to learn more.

Needle Structure Scintillator:
The purpose of the scintillator is to convert x-rays to light. A needle structure scintillator helps to focus the photons in a straight, downward fashion, eliminating unwanted scatter. Most companies utilize a granular structure scintillator, which generates scatter and unwanted noise.

Fiber Optic Plate:
The fiber optic plate improves image quality by stopping nonconverted x-rays from interacting directly with the CCD, which in return eliminates unwanted noise in the signal. It also helps to focus the photons and apply them to the CCD in an even fashion.

CCD:
A unique manufacturing process enables us to provide a CCD with little or no blemishes. This almost flawless CCD requires no correction file, which drastically improves hardware performance. A correction file is software that is needed to fix defects in the hardware. With no correction file your sensor will be ready instantly, and more importantly you won’t have to worry about your sensor timing out during the capture process. Eliminating the need for a correction file also improves workflow with multiple sensors.

Bio-Ray SDX:
By utilizing a unique manufacturing process combined with the ideal materials for dental CCD imaging, and one of the smallest pixel sizes available, Bio-Ray SDX offers superior resolution and image quality. Sigma Digital X-ray combines superior hardware, software and service, making the Bio-Ray SDX the best Intraoral Digital Radiography System available today.

Schematic of a Scintillator-CCD Detector

Schematic of a Scintillator-CCD Detector. Incident X-ray photons interact with the scintillator where they are absorbed and light photons are emitted. Light photons enter the fiber optic plate and are carried to the CCD where they are detected and converted to electrons.

Comparison between a needle and granular scintillator material

These illustrations show the emission spectra, decay, and X-ray absorption coefficient characteristics between the needle and granular scintillator materials. The Bio-Ray SDX uses a needle structure scintillator, as seen here on the left. This comparison clearly shows how the needle structure scintillator eliminates unwanted scatter.

FeatureBenefit
FDA approvedApproved to the Highest International Standards, therefore you can be assured of the quality of Bio-Rays performance
USB port
True plug and play technology, which means you don’t need an IT expert
Needle scintillator
Each image gives you the best clarity and resolution available
Detailed and consistent images
Helps you diagnose easily giving your patients better treatment
Versatile imaging software open architecture
Only Bio-Ray has this feature which enables you to have only one software program to run all your equipment in the clinic
Bridges with Exact and Practice Works and virtually all management programs
Therefore you don’t need any changes to your  present practice management program
Patented name grabber technology
If you don’t have a Practice Management Program you won’t need one to run the Bio-Ray
Apteryx Software
You will get the latest software based on Windows 98+ applications that allows you to view images in many different formats
3 year standard manufacturer warranty
You get peace of mind
Free software upgrades as your needs change
There are no hidden on going costs to your practice to keep updated with software upgrades
Troll positioning systems / permanent / autoclave
Uses well known Troll positioners so that you are not locked in to one supplier and you get reliable systems that are autoclavable
Options Bio-Ray X-Ray Vision or Bio-Ray XV Lite imaging software
You can choose the program to suit your budget and your practice
No fault warranty insurance (no cost)
If you accidentally break the sensor we will replace it for 50% of the selling price for the first three years. There is no additional cost to you for this cover

Intraoral Sensor Specifications:

Sensor Size
Size 1
Size 2
Pixels in sensor
1.52.04
Pixel Size
20 x 20
20 x 20
Active Image Area (mm)
30 x 20
34 x 24
Resolution
25
25
External Dimensions (mm)
38.5 x 26.2
42.5 x 30.5



Bio-Ray Intraoral Digital Radiography System Includes:
•    Bio-Ray SDX Sensor
•    Bio-Ray SDX USB Interface
•    Single User Imaging Software
•    Sensor Positioning System
•    Sensor Sheaths

Advantages of using the Bio-Ray System:
•    Exceptional Customer Support and Reliability
•    Affordable Price
•    Exceptional Quality Eliminates Downtime
•    Detailed and Consistent Images
•    Bridges with Virtually all Practice Management Software

•    Bio-Ray SDX Sensor •    Bio-Ray SDX USB Interface •    Single User Imaging Software •    Sensor Positioning System •    Sensor Sheaths•    Exceptional Customer Support and Reliability •    Affordable Price •    Exceptional Quality Eliminates Downtime •    Detailed and Consistent Images •    Bridges with Virtually all Practice Management Software

* price applies to size 1 sensor only, please contact us for size 2 pricing*


 
 
 
© 2012 DRC. All Rights Reserved. Log in
 

Online Sales & Marketing - Exceed Online